55
M1.0-1055-060
LUBRICATION & ADJUSTMENT
Componentry
FU5
TCM
Location: distribution panel.
Purpose: protect Access 2/Access 3 logic circuitry and
associated wiring from overcurrent.
Data: 5A current.
Adjustment: none required.
FU13/FU14
Freezer/Corrosion
Location: freeze/corrosion distribution panel.
Purpose: protect freezer condition components and
wiring from overcurrent.
Data: 15A current.
Adjustment: none required.
HGTS1
Height Switch 1
Location: mast at staging.
Purpose: provides speed limit input when forks are
above free lift, provides lift/tilt interlock and reduces
braking deceleration when forks are above free lift.
Data: wired normally closed - held closed when mast is
below staging. 36VDC.
Adjustment: none required.
Figure 16049