ELECTRICAL
Event Code 204
232
M4.8-1055-022
03 Rev. 10/09
Event Code 204
Hydraulic motor current Low while motor is run-
ning (DC or AC Hydraulic models).
Step 1: Verify hydraulic motor cables are connected to
proper terminals at ACCESS 2 and motor.
If: Connections not correct.
Connect properly.
If: Connections correct.
Then proceed to Step 2.
Step 2: Check for loose coil connections at P contactor,
CA411-8 and CA411-9, and at ACCESS 2 (AC) con-
nector CA409-2 and CA409-8 and at ACCESS 2 (DC)
connector CA405-26, CA405-27.
If: Correct.
Then replace ACCESS 2.
If: Not correct.
Then repair as necessary.
Figure 15997-01
Crown 2007 PF15665-22 Rev. 10/09