ELECTRICAL
Event Code 218
242
M4.8-1055-032
03 Rev. 10/09
Event Code 218
ECR4 (Hyd Sensor bearing) Feedback Issue.
Hydraulic motor encoder feedback does not match
ACCESS 2 output.
Step 1: From ACCESS 1, Level 2, proceed to Service
Analyzer menu A2.2.8 and A2.2.9 and monitor ECR4
and RPM Target inputs while operating lift. Range is
800 to 3200 RPM.
If: Inputs within range.
Then replace ACCESS 2.
If: Inputs do not follow changes in motor speed dur-
ing operation.
Then proceed to Step 2.
Step 2: Use DVOM to check from positive (CA420-3)
and negative (CA420-6) at Hydraulic motor. Power
supply should be approximately 11.3 Vdc.
If: OK.
Then proceed to Step 3.
Step 3: Use DVOM to check from positive (CA405-1)
and negative (CA405-2) at ACCESS 2. Power supply
should be approximately 11.3 Vdc.
If: OK
Then repair/replace wiring/connection between
CA405 and CA420.
If: Less than 11.3 Vdc.
Then replace ACCESS 2.
Step 4: Check ECR4 wiring for proper continuity from
ACCESS 2 to pump connector CA405-13 (Ch A) to
CA420-5 and CA405-14 (Ch B) to CA420-4. Verify wir-
ing not shorted.
If: Wiring not OK.
Then repair/replace wiring or connections.
If: Wiring checks OK.
Then replace sensor bearing (ECR4).
Figure 16018
Crown 2007 PF15665-32 Rev. 10/09