Crown RC 5500 series - Event Code 217

Crown RC 5500 series
691 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
241
M4.8-1055-031
03 Rev. 10/09
ELECTRICAL
Event Code 217
Event Code 217
ACCESS 2 Travel Alarm (ALM2) Reads Short
across Output (DC Hydraulic models).
Step 1: From ACCESS 1, Level 3, Analyzer menu
A4.2.1 and with DVOM across ALM2, test drive output
from ACCESS 2.
If: 33-35 Vdc.
Then output driver is ok, reset code and moni-
tor for reoccurrence.
If: Less than 33-35 Vdc.
Then output driver is not working or is sensing
a short circuit; proceed to Step 2.
Step 2: Check for short from negative wire of ALM2 to
+BV by checking voltage from BNEG to ALM2 positive
wire.
If: 33-35 Vdc.
Then negative wire is shorted to +BV, trace
wire to CA405-28 and repair wiring.
If: Less than 5 Vdc.
Then proceed to Step 3.
Step 3: Disconnect wires and check ALM2 for internal
short using ohmmeter, should read 35 to 45 ohm.
If: Less than 35 ohm.
Then replace ALM2.
If: 35-45 ohm.
Then replace ACCESS 2.
Figure 16017
Crown 2007 PF15665-31 Rev. 10/09