EasyManua.ls Logo

Crown RC 5500 series - Event Code 319

Crown RC 5500 series
691 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
257
M4.8-1055-047
03 Rev. 10/09
ELECTRICAL
Event Code 319
Event Code 319
ACCESS 3 detected the brake switch (BRKS) open-
ing or closing outside the 5-50% brake application
range of the brake sensor (RPS1).
Step 1: Verify brake switch operation in Analyzer menu
A2.3.9.2 is between 18% and 35% when BRKS
changes from 0 to 1 as brake pedal is slowly released
brake pedal and from 1 to 0 as pedal is slowly de-
pressed.
If: BRKS changes outside range.
Then adjust BRKS to actuate at approximately
22 to 27%. Recalibrate brake pedal (RPS1) af-
ter brake switch adjustment.
If: BRKS remains at 0 at 1 regardless of pedal po-
sition.
Then check condition of BRKS and BRKS cir-
cuit for open or short.
If: BRKS changes state inconsistently.
Then replace BRKS.
If: RPS1 does not change state or is erratic.
Then proceed to Step 2.
Step 2: Verify linkage and wiring to RPS1 is correct.
If: Linkage is binding or loose.
Then repair linkage as needed.
If: Linkage is correct
Then proceed to Step 3.
Step 3: Check RPS1 wiring.
If: RPS1 wiring is not secure.
Then repair wiring as needed.
If: RPS1 wiring is secure.
Then proceed to Step 4.
Step 4: Verify RPS1 5 V power supply (CA606-1 and
-3).
If: Power supply is available to RPS1.
Then proceed to Step 6.
If: Power supply is not available to RPS1.
Then proceed to Step 5.
Step 5: Check wiring and voltage from ACCESS 3
(CA403-19 and -33).
If: Power supply is not available from ACCESS 3.
Then replace ACCESS 3.
If: Power supply is available from ACCESS 3.
Then repair wiring from ACCESS 3 (CA403-19
and -33) to RPS1 (CA606-1 and -3).
Step 6: Check RPS1 output voltage, verify RPS1 out-
put ranges from 0.5 to 4.5 Vdc at CA606-3 and -2.
If: RPS1 output does not range consistently be-
tween approximately 0.5 to 4.5 Vdc.
Then replace RPS1.
If: RPS1 output ranges consistently between ap-
proximately 0.5 to 4.5 Vdc.
Then replace ACCESS 3.
If: RPS1 wiring input to ACCESS 3 is not correct.
Then repair wiring to ACCESS 3 as needed.
Figure 15766-01
Crown 2007 PF15665-47 Rev. 10/09

Table of Contents