PLATFORM
Sideshifter
376
M9.0-1055-008
02 Rev. 7/07
Sideshift Circuit Test
WARNING
Avoid high pressure fluids - escaping fluids under pres-
sure can penetrate the skin, causing serious injury. Re-
lieve pressure before disconnecting hydraulic lines.
Turn the truck off and move the truck auxiliary control
handle multiple times in both directions. Tighten all
connections before applying pressure. Keep hands
and body away from pin holes which eject fluids under
high pressure. Use a piece of cardboard or paper to
search for leaks. Do not use your hand.
Any fluid injected into the skin under high pressure
should be considered a serious medical emergency
despite an initial normal appearance of the skin. There
is a delayed onset of pain, and serious tissue damage
may occur. Medical attention should be sought imme-
diately from a specialist who has experience with this
type of injury.
1. Sideshift all the way to the left. Turn the truck off
and relieve pressure from the attachment system.
Disconnect the "sideshift right" supply hose from
the truck hose terminal and direct hose end to drain
bucket. Cap the supply fitting.
2. Start the truck and actuate the "sideshift left" lever
for 5 seconds. If there is substantial hydraulic flow
out of the drain hose, the sideshift cylinder is defec-
tive and must be replaced. See Sideshifter Cylin-
der for cylinder replacement procedures. If there is
no hydraulic flow, check for plugged flow restrictor
washers and fittings, making sure they are also in-
stalled correctly. If there are still no signs of hy-
draulic flow, the problem is not hydraulic.
Figure 16216
1 Sideshift Right Supply Hose
2 Supply Fitting Cap
3 Hose End
Crown 2007 PF15717-8 Rev. 7/07