219
 M4.8-1055-009
03 Rev. 10/09
ELECTRICAL
Event Code 108
Event Code 108
ACCESS 3 loses power.
ACCESS 7 is still powered. A single flashing BDI LED
is displayed if present at start up.
Step 1: Check voltage at CA403-3 (+) and BNEG.
• If: Less than 35 Vdc.
– Then check wiring and fuse, FU5, from KYS to 
FU5 to CA403-3 and repair.
• If: Between 35 to 38 Vdc.
– Then check ACCESS 3 CAN wiring CA401-1 
and CA401-6 and repair. Refer to Event Code 
300 for additional information.
Figure 15778
Crown 2007 PF15665-9 Rev. 10/09