LUBRICATION & ADJUSTMENT
Componentry
58
 M1.0-1055-063
01 Rev. 3/07
K1
Power Up Relay
Location: distribution panel.
Purpose: provides power up, power down sequence
interlock.
Data: 36VDC coil energized upon keyswitch test posi-
tion closure.
Adjustment: none required.
K2
Options
Location: distribution panel.
Purpose: provides power for optional electrical equip-
ment eg. Lights, fan etc.
Data: 36VDC coil energized upon keyswitch test posi-
tion.
Adjustment: none required.
KYS
Key Switch
Location: Access 1 bracket.
Purpose: allows operator to power truck up and shut
truck down by providing battery power to controllers
and power up circuitry.
Data: key operated selector switch. Energizes K1 
w/test position and maintains K1 with run position.
Adjustment: none required.