ELECTRICAL
ACCESS 123...System
182
 M4.3-1055-050
04 Rev. 10/09
row to test. The DVOM should display approximately
24 volts. Press the down arrow to continue.
A4.3.2 FAN2; (power unit fan). Press the right arrow
and then press enter arrow to test. The fan should op-
erate. Press the down arrow to continue.
A4.3.3 HN1; (horn) press right arrow and then press
enter arrow to test. The horn should sound.
Press the left arrow to return to A4.3 ACCESS 3 then
down to continue.
A4.4 ACCESS 7; To test outputs by ACCESS 7 acces-
sory module. Press the right arrow to enter the sub-
menus.
A4.4.1 SPL; (lower proportional valve coil) connect the
DVOM across coil. Press the right arrow and then
press the enter arrow to test. The DVOM should dis-
play approximately 7 volts. Press the down arrow to
continue.
A4.4.2 SPA; (accessory proportional valve coil) con-
nect DVOM across coil. Press the right arrow and then
press the enter arrow to test. The DVOM should dis-
play approximately 7 volts. Press the down arrow to
continue.
A4.4.3 SVTE; (solenoid valve tilt extend coil) connect
DVOM across coil. Press the right arrow and then
press the enter arrow to test. The DVOM should dis-
play approximately 21 volts. Press the down arrow to
continue.
A4.4.4 SVTR; (solenoid valve tilt retract coil) connect
DVOM across coil. Press the right arrow and then
press the enter arrow to test. The DVOM should dis-
play approximately 21 volts. Press the down arrow to
continue.
A4.4.5 SVH; (solenoid valve hoist coil) connect DVOM
across coil. Press the right arrow and then press the
enter arrow to test. The DVOM should display approx-
imately 7.5 volts. Press the down arrow to continue.
A4.4.6 PRVA; (optional proportional accessory relief
valve coil) connect the DVOM across coil. Press the
right arrow and then press the enter arrow to test. The
DVOM should display approximately battery volts.
Press the down arrow to continue.
A4.4.7 SVA1A; (optional 1st accessory solenoid valve
A coil) connect the DVOM across coil. Press the right
arrow and then press the enter arrow to test. The
DVOM should display approximately 30 volts. Press
the down arrow to continue.
A4.4.8 SVA1B; (optional 1st accessory solenoid valve
B coil) connect the DVOM across coil. Press the right
arrow and then press the enter arrow to test. The
DVOM should display approximately 30 volts. Press
the down arrow to continue.
A4.4.9 SVA2A; (optional 2nd accessory solenoid valve
A coil) connect DVOM across coil. Press right arrow
and then press enter arrow to test. The DVOM should
display approximately 30 volts. Press the down arrow
to continue.
A4.4.10 SVA2B; (optional 2nd accessory solenoid
valve B coil) connect the DVOM across coil. Press the
right arrow and then press enter arrow to test. The
DVOM should display approximately 30 volts.
Press the left arrow to until you scroll back to Analyzer
menu. Then press the down to continue.
Calibration
If the calibration procedures are not performed cor-
rectly, unsatisfactory truck performance or logged
events may result.
When to Calibrate
• When ACCESS 1, 2, 3, or 7 is replaced, full truck 
calibration is required.
• When any potentiometer, encoder, or component 
used to mount or position a potentiometer or en-
coder is replaced.
During most calibrations, you can press the right arrow 
to view the component input or output value. You can 
use this as a troubleshooting tool if there are problems 
with the calibration process by comparing values with 
a known working truck.
Calibration Error Message
The message "Calibration Failed" may be displayed if
required calibration criteria are not met. This message
may result from improper sequencing of switches to
component issues. If this message is displayed during
calibration, press the enter arrow to repeat calibration
procedures.
Crown 2007 PF15628-50 Rev. 10/09