LUBRICATION & ADJUSTMENT
Componentry
52
M1.0-1055-057
ENLS, ENSR
Entry Bar Switches
Location: left/right sides of entry bar.
Purpose: signals Access 3 to remove power from trac-
tion circuit when operator’s foot is resting on power unit
skirt along operator compartment.
Data: wired normally closed. Operator standing on skirt
actuates switch.
Adjustment: none required.
FNS
Fan Switch
Location: console.
Purpose: allows operator to turn on/off operator fan
and select low/high speed.
Data: Off/high speed/low speed.
Adjustment: none required.
FAN1
Operator Fan
Location: work assist post/A pillar.
Purpose: operator comfort.
Data: 24VDC high speed, 12 volt DC low speed, 1 amp
current draw.
Adjustment: none required.
Figure 15891
Figure 15934
Figure 15892
ENLS and ENSR
Crown 2007 PF15674-8