ELECTRICAL
Event Code 107
218
M4.8-1055-008
03 Rev. 10/09
Event Code 107
SVA3 solenoid coil shorted.
This code only applies to trucks with a 3rd hydraulic
accessory.
Step 1: Disconnect leads from SVA3, connect DVOM
across coil and check resistance.
If: Approximately 0 ohm.
Then coil shorted, replaced coil.
If: Resistance is OK.
Then proceed to Step 2.
Step 2: Disconnect CA205 and CA215. Check for con-
tinuity of wires between connectors.
If: No continuity.
Then repair/replace wiring.
If: Continuity.
Then proceed to Step 3.
Step 3: Connect DVOM to CA205-12 and +BV.
If: 0 V
Then repair/replace distribution panel or wiring.
If: Battery volts
Then proceed to Step 4.
Step 4: Connect DVOM to CA215-23 and CA205-12.
Enter Level 3, navigate to Analyzer menu A4.1.4 SVA3.
Press enter on the display and record DVOM reading.
If: Approximately 30 V.
Check for loose connections, power up truck
and monitor operation.
If: Less than approximately 30 V
Replace ACCESS 1.
Figure 15777-01
Crown 2007 PF15665-8 Rev. 10/09