LUBRICATION & ADJUSTMENT
Componentry
SVBy
Bypass Solenoid
Location: mast manifold.
Purpose: provide hydraulic flow path to reservoir for
excess oil generated while steering.
Data: 24VDC.
Adjustment: none required.
SVA1A
First Accessory Solenoid
Location: mast manifold.
Purpose: provide hydraulic flow direction for first ac-
cessory function - right.
Data: coil energized by Access 7 when first accessory
function selected via POT3. Coil resistance 28.8 ohm
for HI flow and 39.3 ohm for LO flow. Coil voltage
24VDC regardless of battery voltage.
Adjustment: none required.
SVA1B
First Accessory Solenoid
Location: mast manifold.
Purpose: provide hydraulic flow direction for first ac-
cessory function.
Data: coil energized by Access 7 when first accessory
function selected via POT3. Coil resistance 28.8 ohm
for HI flow and 39.3 ohm for LO flow. Coil voltage
24VDC regardless of battery voltage.
Adjustment: none required.