LUBRICATION & ADJUSTMENT
Componentry
60
 M1.0-1055-065
01 Rev. 3/07
LGTS1
Light Switch 1
Location: console.
Purpose: allows operator to turn on/off work assist
lights.
Data: wired normally open - operator toggles switch to
close the contacts and turn on work lights. 36VDC.
Adjustment: none required.
LGT3
Strobe Light
Location: overhead guard.
Purpose: provide visual warning of lift truck presence.
Data: 36VDC.
Adjustment: none required.
LGT4
Dome Light
Location: work assist.
Purpose: provide lighted work area inside operator
compartment.
Data: 12.8VDC, 1.44 amp use 20 ohm resistor in se-
ries with light.
Adjustment: none required.
Figure 15913
Figure 15914
Figure 15915
Crown 2007 PF15674-16 Rev. 3/07