LUBRICATION & ADJUSTMENT
Componentry
68
 M1.0-1055-073
01 Rev. 3/07
SVTR
Tilt Retract
Location: mast manifold.
Purpose: provide hydraulic flow for tilt function.
Data: 24 nominal operating voltage.
Adjustment: none required.
SVT
Tilt Solenoid
Location: mast manifold.
Purpose: provide hydraulic flow direction for tilt func-
tion.
Data: coil energized by Access 7 when tilt function is
selected via TBS or TDS. Coil resistance 39.3 ohms.
Coil voltage 24VDC regardelss of battery voltage.
Adjustment: none required.
SVH
Hoist Solenoid
Location: mast manifold.
Purpose: provide hydraulic flow path for raise/lower
function.
Data: coil energized by Access 7 when raise function
selected via POT2. Coil resistance 28.8 ohm. Coil volt-
age 24VDC regardless of battery voltage.
Adjustment: none required.
Figure 16054
Figure 15946
Figure 15936
Crown 2007 PF15674-24 Rev. 3/07