M1.0-1055-054
LUBRICATION & ADJUSTMENT
Componentry
CVR
Check Valve Lower
Location: mast manifold.
Purpose: prevents mast from drifting down (loaded/
unloaded).
Data: allows hydraulic flow in only one direction.
Adjustment: none required.
DLS
Dome Light Switch
Location: console.
Purpose: turn on/off dome light.
Data: toggle switch wired normally open.
Adjustment: none required.
DMS1, DMS2, DMS3
Foot Presence Switches
Location: right side of floorboard.
Purpose: indicates right foot presence.
Data: wire normally open - held open when nothing on
pedal.
Adjustment: none required.