EasyManua.ls Logo

Crown RC 5500 series - Event Code 722

Crown RC 5500 series
691 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
275
M4.8-1055-065
03 Rev. 10/09
ELECTRICAL
Event Code 722
Event Code 722
CAN Communication between ACCESS 7 and
ACCESS 2 Time Out.
Lost CAN communication between ACCESS 7 and
ACCESS 2.
Step 1: Check for other event codes and troubleshoot
them first.
If: No other event codes.
Then proceed to Step 2.
Step 2: Verify ACCESS 2 remains powered at time of
code. Check voltage from CA405-33 (+) and BNEG.
(CA409-1 (+) and BNEG on AC hydraulic models).
If: Not powered.
Then repair power supply wiring.
If: ACCESS 2 remains powered.
Then proceed to Step 3.
Step 3: Key OFF truck and check CAN high and low
lines with DVOM for proper resistance at harness. Con-
nect leads to CA405-18 and CA405-19 (DC) or
CA406-3 and CA406-1 (AC), should be approximately
60 ohm.
If: 0 ohm.
Then a short exists between CAN high and
CAN low. Check wiring and repair.
If: Greater than 60 ohm.
Then check wiring for open or bad connection.
If OK, then replace ACCESS 2.
If: 60 ohm.
Then CAN line is correct, replace ACCESS 2 if
code continues.
Figure 16078
Crown 2007 PF15665-65 Rev. 10/09