LUBRICATION & ADJUSTMENT
Componentry
56
 M1.0-1055-061
01 Rev. 3/07
HGTS2
Height Switch 2
Location: mast at variable heights below staging.
Purpose: provides lift/tilt interlock at specified heights
and specified degrees of tilt for trucks with 10° forward
tilt for Quad/TT.
Data: wire normally closed. Closed when fork carriage
reaches specified heights. 36VDC.
Adjustment: none required.
HGTS3
Height Switch 3
Location: mast at variable heights above staging.
Purpose: provides lift/tilt interlock at specified heights
and specified degrees of tilt for trucks with 10° forward
tilt for Quad/TT.
Data: wire normally closed. Closed when fork carriage
reaches specified heights. 36VDC.
Adjustment: none required.
HGTS4
Height Switch 4
Location: mast at variable heights above staging.
Purpose: provides lift/tilt interlock at specified heights
and specified degrees of tilt for trucks with 10° forward
tilt for TT.
Data: wire normally closed. Closed when fork carriage
reaches specified heights. 36VDC.
Adjustment: none required.
Figure 15902
Figure 16240
Figure 16241
Crown 2007 PF15674-12 Rev. 3/07