EasyManua.ls Logo

Crown RC 5500 series - Event Code 751

Crown RC 5500 series
691 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
295
M4.8-1055-085
03 Rev. 10/09
ELECTRICAL
Event Code 751
Event Code 751
ACCESS 2 Startup Miscommunication.
This event code occurs at startup when the ACCESS 7
retrieves Access identification.
Step 1: Measure input voltage to ACCESS 2 during
event at +BV and BNEG.
If: 35-38 Vdc and stable during event.
Then proceed to Step 2.
If: Not 35-38 Vdc and stable.
Then repair power circuit to ACCESS 2.
Step 2: Check CAN wiring by following event code
733.
If: CAN wiring is bad.
Then repair CAN network.
If: CAN wiring is correct.
Then proceed to Step 3.
Step 3: Check for additional event codes.
If: Only event code 751 occurs.
Then replace ACCESS 2.
If: Event code 751 occurs with 748, 749 or 750
codes.
Then replace ACCESS 7.
Event Code 752
ACCESS 1 Software not compatible with
ACCESS 7 Software.
Software not compatible with ACCESS 7 software.
Step 1: Enter the Utilities menu U1.1.2 and U1.4.2 and
record software part numbers. Contact Crown for soft-
ware updates.
Event Code 753
ACCESS 3 Master Software not compatible with
ACCESS 7 Software.
ACCESS 3 master software not compatible with
ACCESS 7 software.
Step 1: Enter the Utilities menu U1.3.2 and U1.4.2 and
record software part numbers. Contact Crown for soft-
ware updates.
Event Code 754
ACCESS 3 Slave Software not compatible with
ACCESS 7 Software.
ACCESS 3 Slave software not compatible with
ACCESS 7 software.
Step 1: Enter the Utilities menu U1.3.2 and U1.4.2 and
record software part numbers. Contact Crown for soft-
ware updates.
Event Code 755
ACCESS 2 Software not compatible with
ACCESS 7 Software.
ACCESS 2 software not compatible with ACCESS 7
software.
Step 1: Enter the Utilities menu U1.2.2 and U1.4.2 and
record software part numbers. Contact Crown for soft-
ware updates.
Event Code 799
ACCESS 7 Internal Fault.
ACCESS 7 has logged an event indicating an internal
problem exists.
Step 1: Key down truck, then key-up.
If: Code continues.
Then load current software in ACCESS 7.
If: Code continues.
Then replace ACCESS 7.
Crown 2007 PF15665-85 Rev. 10/09