LUBRICATION & ADJUSTMENT
Componentry
62
M1.0-1055-067
01 Rev. 3/07
ORS
Override (Lift Cutout) Switch
Location: console.
Purpose: allows operator to override height encoder/
limit switch and continue raising.
Data: momentary contact wired normally open - oper-
ator toggles switch to close the contacts and provide
override function.
Adjustment: none required.
PCA
Pressure Compensator Valve
Location: mast manifold.
Purpose: provides priority and compensated flow con-
trol for tilt and accessory functions.
Data: not applicable.
Adjustment: none required.
POT1
Accelerator Potentiometer
Location: multi-task handle.
Purpose: provides input to controller for speed.
Data: 1.7 K ohm.
Adjustment: refer to maintenance section.
Figure 15919
Figure 15940
Figure 15920
Crown 2007 PF15674-18 Rev. 3/07