233
M4.8-1055-023
03 Rev. 10/09
ELECTRICAL
Event Code 205
Event Code 205
ACCESS 2 detecting incorrect current in feedback
circuit at standby (AC or DC Hydraulic models).
Step 1: Verify hydraulic motor cables are connected to
proper terminals at ACCESS 2 and motor.
If: Connections not correct.
Connect properly.
If: Connections correct.
Then proceed to Step 2.
Step 2: Check for open hydraulic motor. Remove
power cables from hydraulic motor. Measure and
record resistance across each of the following phases
(U to V), (U to W), (V to W) - AC or (A to D) - DC.
If: Open or greater than 1 ohm.
Then replace motor/brushes DC.
If: Less than 1 ohm resistance.
Then replace ACCESS 2.
Figure 15998-01