ELECTRICAL
Electrical System
126
M4.1-2720-006
03 Rev. 10/06
How the Switch is Activated
If it is necesary to include how the switch is mechani-
cally actuated, a note will be added to the drawing (ex-
ample: operator, lever or truck actuated, etc.)
Application
Switch application is conveyed through the abbrevia-
tion (example: HTS = Height Switch 120 in., DTS =
Drive/Tow Switch).
Notes:
• In a schematic, the condition of a circuit is defined
using a note (example: vehicle shown fully low-
ered with no operator on vehicle).
• Positive action switches are marked with the fol-
lowing symbol:
Examples (All Momentary)
With Common (Transfer) Without Common (Double Break)
Wired normally
open, held open
Figure 8119-01 Figure 8120-01
Wired normally
open, held closed
Figure 8122
Figure 8123
Wired normally
closed, held open
Figure 8115-01 Figure 8117-01
Wired normally
closed, held closed
Figure 8124 Figure 8125
8126-02
Crown 2000 PF11845-6 Rev. 10/06