ELECTRICAL
ACCESS 123...System
180
M4.3-1055-048
04 Rev. 10/09
A3.1.5 ALM2; (travel alarm output) depending on how
features menu F9 Travel Alarm is set, ALM2 may
sound when traveling in reverse, forward or both direc-
tions. To view output, press the right arrow and sound
the alarm. Alarm activated - approximately 100%.
Alarm not activated - 0%. Press the left arrow twice to
return to A3.1 ACCESS 1 Outputs submenu then down
arrow to continue.
A3.2 ACCESS 2; View outputs by ACCESS 2 hydrau-
lic module. Press the right arrow to enter the sub-
menus.
A3.2.1 ALM1; (incorrect operator sequence alarm out-
put) to view output, press the right arrow and sound
alarm. Alarm activated - On. Alarm not activated - Off.
Press the left arrow to return to A3.2.1 ALM1 submenu
then down arrow to continue.
A3.2.2 P; (pump contactor coil output). To view output,
press the right arrow. Floor pedals depressed - ON.
Floor pedals released and timed out - OFF. Press the
left arrow twice to return to A3.2 ACCESS 2 submenu
and then down arrow to continue.
A3.3 ACCESS 3; View outputs by ACCESS 3 traction
module. Press the right arrow to enter the submenus.
A3.3.1 L; (line contactor coil output). To view output,
press the right arrow. Floor pedals depressed - ON.
Floor pedals released and timed out - OFF. Press the
left arrow to return to A3.3.1 L submenu then down ar-
row to continue.
A3.3.2 FAN2; (power unit fan output). To view output,
press the right arrow. Fan "running" - ON, fan not "run-
ning" - OFF. Press left arrow to return to A3.3.2 FAN2
submenu then down arrow to continue.
A3.3.3 HN1; (horn output). To view output, press the
right arrow and sound horn. Horn activated - ON. Horn
not activated - OFF. Press the left arrow twice to return
to A3.3 ACCESS 3 submenu then down arrow to con-
tinue.
A3.4 ACCESS 7; View outputs by ACCESS 7 acces-
sory module. Press the right arrow to enter the sub-
menus.
A3.4.1 SPL; (lower proportional valve coil output) to
view output to SPL coil, press the right arrow.
A3.4.1.1 DC; to view output, press the right arrow. Se-
lect full lower and then release the multi-task handle.
Full lower - approximately 40%, no lower - 0%. Press
the left arrow to return to A3.4.1.1 DC submenu then
down arrow to continue.
DC = duty cycle
A3.4.1.2 Current; to view output, press the right arrow.
Select full lower and then release the multi-task handle.
Full lower - approximately 475 mA, no lower - approxi-
mately 2 mA. Press the left arrow twice to return to
A3.4.1 SPL submenu then down arrow to continue.
A3.4.2 SPA; (accessory proportional valve coil output)
to view output to coil, press the right arrow.
A3.4.2.1 DC; to view output, press the right arrow. Se-
lect tilt down and then release thumb ball. Tilt down -
approximately 30%, no tilt - 0%. Press the left arrow to
return to A3.4.2.1 DC submenu then down arrow to
continue.
A3.4.2.2 Current; to view output, press the right arrow.
Select tilt down and then release thumb ball. Tilt down
- approximately 300 mA, no tilt - 2 mA. Press the left
arrow twice to return to A3.4.2 SPA submenu then
down arrow to continue.
A3.4.3 SVTE; (solenoid valve tilt extend output) to view
output, press the right arrow and activate/de-activate
function. Tilt down - approximately 60%. No tilt - ap-
proximately 0%. Press the left arrow to return to A3.4.3
SVTE submenu then down arrow to continue.
A3.4.4 SVTR; (solenoid valve tilt retract output) to view
output, press the right arrow and activate/de-activate
function. Tilt back - approximately 60%. No tilt - approx-
imately 0%. Press the left arrow to return to A3.4.4
SVTR submenu then down arrow to continue.
A3.4.5 SVH; (solenoid valve hoist coil output) to view
output, press the right arrow and select raise. Raise -
approximately 65%. No raise - approximately 0%.
Press the left arrow to return to A3.4.5 SVH submenu
then down arrow to continue.
A3.4.6 PRVA; (optional proportional accessory relief
valve coil output) to view output to PRVA coil, press the
right arrow.
A3.4.6.1 PWM; View percent of pulse width modula-
tion (duty cycle). Press the right arrow and actuate ac-
cessory function that requires pressure setting. Press
the left arrow to return to A3.4.6.1 PWM and then the
down arrow to continue.
A3.4.6.2 Current; to view output, press the right arrow
and actuate accessory function that requires pressure
setting. Press the left arrow to return to A3.4.6.2 cur-
rent and then the down arrow to continue.
Crown 2007 PF15628-48 Rev. 10/09