Using the Equipment
EN/LZT 790 0005 R7A
3-235
3.13.9.6 Configuration
Figure 3.110 Frame Sync Fields
The Frame-Sync is configured using the following menu options.
Frame SyncEnables or disables Frame-Sync mode.
Frame Sync StatusReports the current Frame-Sync status.
- Sync SD Frame-sync for the decoded SD video is successful
- Sync HDFrame-sync for the decoded HD video is successful
- Syncing… - A frame-sync source or reference feed has been detected but
the IRD has not acquired a lock yet
- DisabledFrame-sync mode is disabled, or no frame-sync source or
reference feed has been detected
- No SignalFrame-sync mode is enabled but no frame-sync source or
reference feed has been detected
- Mismatch Format - Frame-sync mode is enabled and detected but the
frame-rate is incorrect
Frame Sync Status for 1080pReports the current Frame-Sync status when
decoding 1080p video formats.
- Sync HDFrame-sync for the decoded 1080p video is successful
- Syncing… - A frame-sync source or reference feed has been detected but
the IRD has not acquired a lock yet
- DisabledFrame-sync mode is disabled, or no frame-sync source or
reference feed has been detected
- No SignalFrame-sync mode is enabled but no frame-sync source or
reference feed has been detected
- Mismatch Format - Frame-sync mode is enabled and detected but the
frame-rate is incorrect

Table of Contents