Using the Equipment
3-388
EN/LZT 790 0005 R7A
2. The unit should now be tested for connectivity. To do this, open a DOS window
on the networked PC. At the DOS prompt type:
ping <ip address>
3. If the unit is successfully connected to the network, some replies should be seen
at the DOS prompt, these will be of the form:
reply from <ip address> bytes =32 time = nn TTl =nn
Note: If no valid replies are seen then steps 1 to 3 should be repeated.
4. The batch file updateallrx8000.bat is supplied with the code package. This
batch file allows the update of code to either flash bank of the RX8000 and also
allows option cards to be upgraded.
5. Ensure the batch file updateallrx8000.bat is placed on the networked PC in the
same directory as the new image file main.bin and any other option card
software images.
6. Using a DOS window, navigate the directories until the directory with the above
two files is accessible.
7. At the DOS prompt type:
Updateallrx8000.bat
8. The batch file will now prompt the user for the IP address of the unit to be
upgraded. The IP address of the unit should be entered in the same way as
circled in the example below followed by pressing Enter.
9. The batch file will now prompt for the board type to be upgraded. This will be
either the Mainboard code or one of the option cards installed on the unit. The
choice is entered in the same way as circled in the example below followed by
pressing Enter.