CAUTION: Before removing or installing components of a device, connect an
electrostatic discharge (ESD) grounding strap to an ESD point and wrap and fasten the
other end of the strap around your bare wrist. Failure to use an ESD grounding strap
could result in damage to the device.
Install the device in compliance with the following local, national, and international electrical codes:
United States—National Fire Protection Association (NFPA 70), United States National Electrical Code.
Other countries—International Electromechanical Commission (IEC) 60364, Part 1 through Part 7.
Evaluated to the TN power system.
Canada—Canadian Electrical Code, Part 1, CSA C22.1.
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National
Electrical Code and NFPA 75.
Peut être installé dans des salles de matériel de traitement de l’information conformément à l’article
645 du National Electrical Code et à la NFPA 75.
Locate the emergency power-off switch for the room in which you are working so that if an electrical
accident occurs, you can quickly turn off the power.
Make sure that grounding surfaces are cleaned and brought to a bright finish before grounding connections
are made.
Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
Never assume that power is disconnected from a circuit. Always check the circuit before starting to
work.
Carefully look for possible hazards in your work area, such as moist floors, ungrounded power extension
cords, and missing safety grounds.
Operate the device within marked electrical ratings and product usage instructions.
To ensure that the device and peripheral equipment function safely and correctly, use the cables and
connectors specified for the attached peripheral equipment, and make certain they are in good condition.
You can remove and replace many device components without powering off or disconnecting power to
the device, as detailed elsewhere in the hardware documentation for this device. Never install equipment
that appears to be damaged.
241

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX5110 Series and is the answer not in the manual?

Juniper QFX5110 Series Specifications

General IconGeneral
Rack Units1U
Operating SystemJunos OS
Form FactorFixed
ManagementCLI, SNMP, NETCONF
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 90% non-condensing
AC Power Input100-240 VAC
Power SupplyRedundant, hot-swappable