Table 91: Access Port LEDs on QSFP+ Ports on a QFX3600 Device (continued)
DescriptionStateColorLED
No transceiver is installed in the port, or the transceiver is not
supported.
OffUnlitStatus
A transceiver is installed in the port.On steadilyGreen
Table 92 on page 522 describes the QSFP+ uplink port LEDs.
Table 92: Uplink Port LEDs on a QFX3600 or QFX3600-I Device
DescriptionStateColorLED
No link is established, there is a fault, or the link is down.OffUnlitLink/Activity
A link is established, but there is no link activity.On steadilyGreen
A link is established, and there is link activity.Blinking
No transceiver is installed in the port, or the transceiver is
not supported.
OffUnlitStatus
A transceiver is installed in the port.On steadilyGreen
RELATED DOCUMENTATION
Front Panel of a QFX3600 Device | 48
Front Panel of a QFX3600-I Interconnect Device
Installing a Transceiver in a QFX Series Device | 481
Connecting a Fiber-Optic Cable to a QFX Series Device | 488
Fan Tray LED on a QFX3600 or QFX3600-I Device
Figure 194 on page 523 shows the location of the LED on the fan tray.
522

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX5110 Series and is the answer not in the manual?

Juniper QFX5110 Series Specifications

General IconGeneral
Rack Units1U
Operating SystemJunos OS
Form FactorFixed
ManagementCLI, SNMP, NETCONF
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 90% non-condensing
AC Power Input100-240 VAC
Power SupplyRedundant, hot-swappable