Page #481 background image
Figure 161: Removing a Power Supply from a QFX3500 Device
CO
C1
g050026
RELATED DOCUMENTATION
AC Power Supply for a QFX3500, QFX3600, or QFX3600-I Device
Connecting AC Power to a QFX3500, QFX3600, or QFX3600-I Device | 309
Installing a Power Supply in a QFX3500 Device | 453
Installing a Fan Tray in a QFX3500 Device
The fan trays in a QFX3500 device are hot-removable and hot-insertable field-replaceable units (FRUs):
you can remove and replace them without powering off the device or disrupting device functions.
CAUTION: Replace a failed fan tray with a new fan tray within 1 minute of removal
to prevent chassis overheating. Before removing the fan tray, ensure you have a
replacement fan tray.
NOTE: The fan tray provides FRU-to-port or port-to-FRU airflow depending on the device model
you purchase.
Before you install a fan tray in a QFX3500 device, ensure that you have taken the necessary precautions
to prevent electrostatic discharge (ESD) damage (see “Prevention of Electrostatic Discharge Damage” on
page 242).
457

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX5110 Series and is the answer not in the manual?

Juniper QFX5110 Series Specifications

General IconGeneral
Rack Units1U
Operating SystemJunos OS
Form FactorFixed
ManagementCLI, SNMP, NETCONF
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 90% non-condensing
AC Power Input100-240 VAC
Power SupplyRedundant, hot-swappable