Table 134: QFX3500 Chassis Alarm Messages (continued)
Recommended ActionCLI MessageAlarm TypeComponent
Check the system log for the following
message and report it to customer
support:
Temp sensor sensor-number failed,
where sensor-number may range from
1 through 10.
sensor-location Temp Sensor FailMajor (red)Temperature
Sensors
Check environmental conditions and
alarms on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) are
not affecting the temperature sensor.
If the condition persists, the device
may shut down.
sensor-location Temp Sensor Too Hot
For information only. Check
environmental conditions and alarms
on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) are
not affecting the temperature sensor.
sensor-location Temp Sensor Too
Warm
Minor (yellow)
RELATED DOCUMENTATION
Front Panel of a QFX3500 Device | 56
Configuring Junos OS to Determine Conditions That Trigger Alarms on Different Interface Types
alarm
Interface Alarm Messages
Interface alarms are alarms that you configure to alert you when an interface is down.
To configure an interface link-down condition to trigger a red or yellow alarm, or to configure the link-down
condition to be ignored, use the alarm statement at the [edit chassis] hierarchy level. You can specify the
ethernet, fibre-channel, or management-ethernet interface type.