replacement power supply ready: the power supplies or a blank cover panel must be installed in the
device to ensure proper airflow.
CAUTION: Replace a failed power supply with a blank panel or new power supply
within 1 minute of removal to prevent chassis overheating.
RELATED DOCUMENTATION
AC Power Supply for a QFX3500, QFX3600, or QFX3600-I Device
AC Power Supply LEDs on a QFX3500, QFX3600, or QFX3600-I Device | 523
Connecting DC Power to a QFX3500, QFX3600, or QFX3600-I Device
The QFX3500, QFX3600, and QFX3600-I devices are shipped from the factory with two 650 W power
supplies pre-installed. Each power supply is a hot-removable and hot-insertable field-replaceable unit
(FRU) when the second power supply is installed and running. You can install replacement power supplies
without powering off the device or disrupting the switching function.
WARNING: DC-powered QFX3500, QFX3600 and QFX3600-I devices are intended
for installation only in a restricted access location.
NOTE: The battery returns of the DC power supply should be connected as an isolated DC
return (DC-I).
Before you begin connecting DC power to the device:
•
Ensure that you have taken the necessary precautions to prevent electrostatic discharge (ESD) damage
(see “Prevention of Electrostatic Discharge Damage” on page 242).
•
Ensure that you have connected the device chassis to earth ground.
312