Table 52: Details of the AC Power Supplies in EX4300 Switches (continued)
1400 W AC
Power Supply
1100 W AC
Power Supply
715 W AC Power
Supply
350 W AC Power
SupplyDetails
Front-to-back,
indicated by label
AIR OUT (AFO)
Front-to-back,
indicated by label
AIR OUT (AFO)
Front-to-back,
indicated by label
AIR OUT (AFO)
Front-to-back,
indicated by label
AIR OUT (AFO)
Back-to-front,
indicated by label
AIR IN (AFI)
Airflow
1111AC power cord retainer
IN OK and OUT
OK
IN OK and OUT
OK
IN OK and OUT
OK
IN OK and OUT OKPower supply status LEDs
Low line:
100–140 VAC
High line:
200–240 VAC
Low line:
115–120 VAC
High line:
200–240 VAC
Low line:
100–120 VAC
High line:
200–240 VAC
Low line:
100–120 VAC
High line:
200–240 VAC
Operating range
NOTE: In EU countries, Egypt, Nigeria, Saudi Arabia, Serbia, South Korea, and South Africa, you
must ensure that the redundant power supply is installed in the switch chassis.
To prevent electrical injury while installing or removing AC power supplies, carefully follow instructions
in “Installing an AC Power Supply in an EX4300 Switch” on page 465 and Removing an AC Power Supply from
an EX4300 Switch.
AC Power Supply Airflow
Each power supply has its own fan and is cooled by its own internal cooling system.
Each power supply has a label AIR OUT (AFO) or AIR IN (AFI) on the faceplate of the power supply that
indicates the direction of airflow in the power supply.
Table 53 on page 174 lists the AC power supply models and the direction of airflow in them.
173

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper QFX5110 Series and is the answer not in the manual?

Juniper QFX5110 Series Specifications

General IconGeneral
Rack Units1U
Operating SystemJunos OS
Form FactorFixed
ManagementCLI, SNMP, NETCONF
Operating Temperature32°F to 104°F (0°C to 40°C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 90% non-condensing
AC Power Input100-240 VAC
Power SupplyRedundant, hot-swappable

Related product manuals