EasyManua.ls Logo

Kikusui TOS9301 - ACW Test (PASS Judgment)

Kikusui TOS9301
340 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TOS93 Series User’s Manual 323
Appendix | Timing Charts
ACW test (PASS judgment)
Setting conditions
Model: TOS9301
Rise Time: ON
Test Time: ON
Fall Time: ON
Pass Hold: 50 ms
No load (waveform monitoring with a high voltage probe), start the test with the SIGN
AL I/O.
No. Description No. Description
(1) 5 ms min. (6) Fall Time
(2)
Approx. 20 ms
1
1 TYP (typical value)
(7)
Approx. 5 ms
*1
(3)
Approx. 30 ms
*1
(8) Pass Hold
(4) Rise Time (9)
Approx. 2 ms
*1
(5) Test Time
START
H.V ON
TEST
(1)
(3)
(4) (5)
Output
voltage
PASS
READY
(2)
(6)
(7) (8)
(9)

Table of Contents