Diagnostic information 2-23
4062
201.80 Operator panel door
assembly interlock
switch open failure
Type 2 fuser
Fuser page count has
exceeded life
The printer detected that the
switch (operator panel door
interlock) did not cycle prior to
printer restart.
1. Remove all media present
in media path.
2. Ensure that the operator
panel door assembly is fully
open then fully closed.
3. Check operator panel door
assembly for damage.
4. Check interlock switch (in
left operator panel hinge)
for damage.
5. Check all connections on
the system card assembly.
201.81 Sensor (narrow
media) late jam
Type 2 fuser
Fuser page count has
exceeded life.
The media is late reaching the
sensor (narrow media) within
the specified time.
Go to sensor (narrow media)
late jam service check.
See “Sensor (narrow media)
late jam service check.” on
page 2-131.
201.82 Sensor (fuser output)
late jam
Type 2 fuser
Fuser page count has
exceeded life
The media is late reaching the
sensor (fuser output) within the
specified time.
Go to sensor (fuser output) late
jam service check.
See “Sensor (fuser output)
late jam service check.” on
page 2-127.
202.00 Paper jam around
fuser exit or redrive
area.
Type 1 fuser
Page may be jammed in fuser
exit or redrive area.
1. Remove all media present
in media path.
2. Check media for proper
installation.
3. Check for obstructions in
media path.
4. Go to sensor (fuser output)
service check. See
“Sensor (fuser output)
service check” on
page 2-118.
5. Go to sensor (narrow
media) service check. See
“Sensor (narrow media)
service check” on
page 2-119.
202.01 Sensor (fuser output)
lingering jam.
Destination is
standard bin.
Type 1 fuser
Media reached the sensor
(fuser output) but did not clear
it in the specified time.
and
Media did not reach the sensor
(narrow media)
Go to sensor (fuser output)
lingering jam service check.
See “Sensor (fuser output)
lingering jam service check.”
on page 2-129.
202.02 Sensor (fuser output)
lingering jam.
Type 1 fuser
Media reached the sensor
(fuser output) but did not clear
it in the specified time.
Go to sensor (fuser output)
lingering jam service check.
See “Sensor (fuser output)
lingering jam service check.”
on page 2-129.
202.03 Sensor (narrow
media) static jam
Type 1 fuser
Media remains on the sensor
(narrow media) during the
warm up sequence.
Go to sensor (narrow media)
static jam service check.
See “Sensor (narrow media)
static jam service check” on
page 2-132.
Error
code or
message
Error contents Description/Action Possible repair actions