Procedure
............................................................................................................................................................
1
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
Type and enter the RC/V form number.
22.16
Result:
Enter Database Operation R=Review,U=Update:
............................................................................................................................................................
3
Type and enter the update command.
U
Result:
Screen 1 of the PSU PROTOCOL HANDLER CHANNEL
GROUP ASSIGNMENTS page is displayed and the cursor is
located at the SM field.
............................................................................................................................................................
4
Using the RC/V 22.16 form as a guide, type and enter the indicated
values for each field on screen 1.
*SM - Switching Module (1-192)
*PSU - Packet Switch Unit (0)
*PSU SHELF - PSU2 shelf number (0-4)
*VIRTUAL - Virtual PSU2 shelf (Y/N)
............................................................................................................................................................
5
On screen 1 of the PSU PROTOCOL HANDLER CHANNEL
GROUP ASSIGNMENTS page, determine how many PHE2 or PH33
are available.
The number next to AVAILABLE PHE2 or AVAILABLE PH33 is
the number of available PHE2s and PH33s, respectively.
If more PHE2s or PH33s are needed refer to 235-105-231,
Hardware Change Procedures - Growth.
............................................................................................................................................................
6
Proceed to screen 2.
2
PH Channel Group Assignment (RC/V
22.16)