Screen 2 of the PSU PROTOCOL HANDLER CHANNEL
GROUP ASSIGNMENTS page appears.
............................................................................................................................................................
7
To add a PHE2 proceed to step 8.
To add a PHE33 proceed to step 9, not applicable for DRM/VCDX..
............................................................................................................................................................
8
Using screen 2 and/or 3 of RC/V 22.16 as a guide, type and enter the
following information for the PH.
• PH TYPE - PHE2
• AUTO ASSIGN - N
• RMK (optional) - i.e., enter SIPT
Result:
The PHE2 channel group is listed in the CHANNEL GROUPS
(CHNLIST) list.
............................................................................................................................................................
9
Using screen 2 and/or 3 of RC/V 22.16 as a guide type and enter the
following information for the PH.
• PH TYPE - PH33
• AUTO ASSIGN - N
• RMK (optional) - i.e., enter GQPH
NOTE: This step should be skipped for DRM/VCDX..
Result:
PH33 has been provisioned.
............................................................................................................................................................
10
Repeat steps 7-9 for each PH.
............................................................................................................................................................
11
Enter the update command.
U
Result:
Updating...form updated
PH Channel Group Assignment (RC/V
22.16)
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007