2
Type and enter the RC/V form number.
33.1
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
............................................................................................................................................................
3
Type and enter the insert command.
I
Result:
Screen 1 of the INTERNET PROTOCOL (IP) PROCESSOR
ASSIGNMENT page is displayed and the cursor is located at
PROCESSOR ID field.
............................................................................................................................................................
4
Using screen 1 of RC/V 33.1 form as a guide, type and enter the
indicated values for each field.
*PROCESSOR ID - SM number
PROCESSOR TYPE - (For this SIP Platform document,
PROCESSOR TYPE is PH.)
*QUALIFIER 2 - For a PH, this field is the PSU community
address (COM ADDR) found on RC/V 22.2, Packet Switch
Unit).
*QUALIFIER 3 - The 1 digit shelf number and 2 digit channel
group number concatenated).
LOCAL IP ADDR - customer defined
IP SUBNET MASK - customer defined
NOTE: The LOCAL IP ADDR on this view is internal to the
5E-XC
, and is not the IP address known externally to the SIP
signaling network. The external IP address(es) are assigned to the
Ethernet-IP interface on RC/V 33.4, in a separate procedure.
............................................................................................................................................................
5
After entering all LOCAL IP ADDRs and IP SUBNET MASKs;
Type
> and enter to access command line.
............................................................................................................................................................
6
Type and enter screen 2.
Assign PH Channel Group as IP Processor
(RC/V 33.1)