Procedure
............................................................................................................................................................
1
Select and prepare terminal for RC/V activities.
Reference:
“Select and Prepare Terminal” (5-11)
............................................................................................................................................................
2
Type and enter the RC/V form number.
33.4
Result:
Enter Database Operation I=Insert,R=Review,U=Update,
D=Delete:
............................................................................................................................................................
3
Type and enter the insert command.
I
Result:
Screen 1 of the ETHERNET INTERNET PROTOCOL (IP)
INTERFACE ASSIGNMENT page is displayed and the cursor is
located at the SM field.
............................................................................................................................................................
4
Using screen 1 of the RC/V 33.4 form as a guide, type and enter the
parameters.
• *SM - Switching Module number
• *PSU - Packet Switching Unit number
• *SHELF - PSU shelf number
• *CHANNEL GROUP - Channel group position
• #INTERFACE NAME - name of the interface (entries in this
field are case sensitive)
............................................................................................................................................................
5
Proceed to screen 2.
2
Result:
Screen 2 is displayed and the cursor is located at the
GATEWAY IP ADDRESS 1 field.
Insert Ethernet - IP Interface (RC/V 33.4)
Provisioning
....................................................................................................................................................................................................................................
5-42
Lucent Technologies 235-200-118