6
On screen 2 of form 33.4, type and enter the parameters.
#GATEWAY IP ADDRESS 1 - Primary IP address of the
Ethernet-IP interface on the PH
#IP SUBNET MASK 1 - subnetwork mask associated with the
first gateway IP address
GATEWAY IP ADDRESS 2- secondary IP address of the
Ethernet-IP interface on the PH if the processor group to which
the PH belongs will be supporting an SCTP near endpoint; blank
if the PH will be supporting UDP paths
IP SUBNET MASK 2 - subnetwork mask associated with the
GATEWAY IP ADDRESS 2 (leave blank for UDP)
MTU SIZE - 1500
RATE - Rate associated with the speed of the Ethernet link
MODE - mode used for data flow of the Ethernet connection
............................................................................................................................................................
7
Type and enter the insert command.
I
Result:
Inserting...form inserted
NOTE: View MCC 118X,Y,X to see corresponding PH status
change to Active.
............................................................................................................................................................
8
Type and enter the previous screen command.
<
Result:
The INTERNET PROTOCOL VIEWS page is displayed.
............................................................................................................................................................
9
If desired, type and enter the quit command to exit the RC/V system.
Q
Result:
The RC/V session is terminated.
............................................................................................................................................................
10
Stop. You have completed this procedure.