being provisioned, the packet group at the TPS which will receive the
INVITE without ISUP must have TRUST ISUP set to
no. Trust
ISUP=N is the proper setting when connecting a TPS to a proxy and
there are multiple network elements on the other side with varying
capabilities. Trust ISUP=Y is the proper setting when two ‘true’
switches that understand ISUP are directly connected.
NOTE: The service provider is responsible for ensuring proper
coordination of its switches. If SIP without Encapsulated ISUP is
being provisioned, the packet group at the TPS which will receive the
INVITE without ISUP must have an appropriate SIP to PSTN
Interworking Parameter set (RC/V View 5.83) assigned. Refer to the
Feature Description, 235-190-400, document for SIP to PSTN
Interworking Parameter set guidelines.
............................................................................................................................................................
6
Enter the insert command.
I
Result:
Inserting...form inserted
A list of near endpoints is displayed.
............................................................................................................................................................
7
Type and enter the previous screen command.
<
Result:
The TRUNK VIEWS page is displayed.
............................................................................................................................................................
8
If desired, type and enter the quit command to exit the RC/V system.
Q
Result:
The RC/V session is terminated.
............................................................................................................................................................
9
Stop. You have completed this procedure.
Insert SIP Parameters (RC/V 5.82)
Provisioning
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
5-81
E ND OF S TEPS
.........................................................................................................................................................................................................................................................