Procedure
............................................................................................................................................................
1
Execute the Hardware Growth Procedures to install the desired
number of PHE2s and Ethernet Links (1 or 2, for Simplex or Duplex).
Each PHE2 should be in the STBY state on the 118X page for the
PSU shelf on which it resides.
............................................................................................................................................................
2
Use the procedure “PH Channel Group Assignment (RC/V 22.16)”
(5-19) to update the PH TYPE of the desired channel group number(s)
from NULL to PHE2 for the PSU shelf where each PHE2 was
installed.
............................................................................................................................................................
3
Use the procedure “Assign PH Channel Group as IP Processor (RC/V
33.1)” (5-34) to insert each channel group as an IP Processor, with the
MTU ENABLE set to Y, and the IP Parameters identical for both
channel groups that will be used for a duplex processor group.
............................................................................................................................................................
4
Dump the ETHIP/5995 office records. At the MCC or TLWS type and
enter the command:
OP:OFR:FORM=5995;
Result:
The ETHIP/5995 office records are dumped.
............................................................................................................................................................
5
Identify the Ethernet Link numbers that are in use on the existing SIP
GSM and select unused PSELNK number(s) for the new PHE2
Ethernet Link(s).
............................................................................................................................................................
6
Dump the PCRGRP/5883 office records. At the MCC or TLWS type
and enter the command:
OP:OFR:FORM=5883
Result:
OP:OFR:FORM=5883 PF is printed followed by a printout
of the PCRGRP/5883 office records.
............................................................................................................................................................
7
Identify the processor group numbers that are in use on the existing
SIP GSM and select unused PCRGRP number(s) for the new
processor group(s).
Add New SIPT PHE2 IP Processor Group
on an Existing SIP GSM
Provisioning
....................................................................................................................................................................................................................................
5-96
Lucent Technologies 235-200-118
Issue 3.02B, March 2007

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies 5ESS and is the answer not in the manual?

Lucent Technologies 5ESS Specifications

General IconGeneral
BrandLucent Technologies
Model5ESS
CategorySwitch
LanguageEnglish

Related product manuals