Procedure
............................................................................................................................................................
1
Type and enter the RC/V form number.
22.16
Result:
Enter Database Operation R=Review,U=Update:
............................................................................................................................................................
2
Type and enter the update command.
U
Result:
Screen 1 of the PSU PROTOCOL HANDLER CHANNEL
GROUP ASSIGNMENTS page is displayed and the cursor is
located at the SM field.
............................................................................................................................................................
3
Using the RC/V 22.16 form as a guide, type and enter the indicated
values for each field on screen 1.
• *SM - Switching Module (1-192)
• *PSU - Packet Switch Unit (0)
• *PSU SHELF - PSU2 shelf number (0-4)
• *VIRTUAL - Virtual PSU2 shelf (Y/N)
............................................................................................................................................................
4
Proceed to screen 2.
2
Result:
Screen 2 of the PSU PROTOCOL HANDLER CHANNEL
GROUP ASSIGNMENTS page appears.
............................................................................................................................................................
5
Using screen 2 of RC/V 22.16 as a guide type and enter NULL in the
PH TYPE field for each channel group with a PH TYPE set to PHE2
or PH33 and GRP TYPE set to NULL.
............................................................................................................................................................
6
Enter the update command.
U
Result:
Updating...form updated
Update All PHE2 & PH33 Channel Group
Assignments (RC/V 22.16)
Deprovisioning
....................................................................................................................................................................................................................................
6-76
Lucent Technologies 235-200-118
Issue 3.02B, March 2007