Related information
Refer to the Input Messages Manual, 235-600-700 and the Output
Messages Manual, 235-600-750, for additional information.
Admonishments
None
Before you begin
Required Tools
• Use of Master Control Center (MCC)
Required Material
• The switch must be running a 5E16.2 FR3 software release or
later with the SIP for Packet Trunking feature software.
Required Information
• GSM number, PSU number, PSU shelf number
Required Conditions
• None required.
Procedure
............................................................................................................................................................
1
Find the OOS channel group on the MCC which shows as backlit on
the PSU shelf MCC page. Access the PSU 0 SHELF page:
118X,Y,ZZZ
Where:
X = Packet switch unit 2 shelf number
Y = PSU2 number
ZZZ = Global switch module number
When all provisioned PSU2 shelves have been checked and there are
no more
OOS channel groups, then STOP, you have finished this
procedure.
............................................................................................................................................................
2
If there are one or more unassigned channel groups, identify the PH
type, choose an OOS PH of the same type to repair, and CONTINUE
this procedure.
When interrogating unassigned channel groups, it is important to note
the PH hardware type supporting the identified channel group and the
appropriate OOS PH must be analyzed by the remainder of this
procedure.
Resolve Protocol Handler Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
7-36
Lucent Technologies 235-200-118
Issue 3.02B, March 2007