3
If the status of all equipped PHs is OOSF,anACT PSUCOM does not
exist. EXIT this procedure immediately, and refer to the System
Recovery [5E14 and Later Software Releases] procedure, PSU Duplex
Failure, 235-105-250, to resolve the duplex failed PSUCOM situation.
............................................................................................................................................................
4
For the OOS PH, determine detailed status:
OP:CFGSTAT,SM=a,OOS,NOFE;
Where:
a = Global switch module number
Result:
• If the state is OOS-MAN-RMV, PROCEED to Step 5.
• If the state is
OOS-AUTO-RMV, SKIP to Step 7.
• If the state is
OOS-MAN/AUTO-DGN, SKIP to Step 8.
• If the state is
OOS-MAN-EX, SKIP to Step 9.
• If the state is
OOS-AUTO/MAN-FLT, SKIP to Step 10.
• If the state is
OOS-AUTO-TBLA, SKIP to Step 11.
• If the state is
DGR, SKIP to Step 12.
............................................................................................................................................................
5
Restore the PHE2 or PH33:
RST:PSUPH=a-b-c-d;
Where:
a = Global switch module number
b = Packet switch unit 2 number
c = PSU2 shelf number
d = PHE2 number
............................................................................................................................................................
6
Did the PHE2 or PH33 restore successfully to ACT?
• If
yes, RETURN to Step 1
• If
no, RETURN to Step 2
Resolve Protocol Handler Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
7-37