7
The PHE2 or PH33 has been automatically removed for the purpose
of running diagnostics. Allow the diagnostic to be scheduled because
a problem has been detected by fault recovery. After the diagnostics
complete, RETURN to Step 1.
............................................................................................................................................................
8
The PHE2 or PH33 is currently being diagnosed. When the
diagnostics complete, RETURN to Step 1.
............................................................................................................................................................
9
The PH33 is currently being routinely exercised. Because PH channel
groups are unassigned, the routine exercise should be stopped
immediately, then RETURN to Step 1 for re-evaluation.
STP:PSUPH=a-0-b-c;
Where:
a = Global switch module number
b = PSUCOM shelf number
c = Physical PH number
............................................................................................................................................................
10
The PHE2 or PH33 is faulty. Find the most recent printed trouble
location procedure (TLP) list on the ROP. For the PHE2 or PH33,
refer to the Corrective Maintenance procedure, Clear Diagnostic
Failure in Hardware Units/Circuits, 235-105-220.
After the repair is completed, including the attempted restoration of
the PHE2 or PH33, is the PH successfully restored to ACT?
• If
yes, RETURN to Step 1.
• If
no, SEEK TECHNICAL ASSISTANCE according to local
procedures for the affected PH.
If the channel groups on the target shelf are still unassigned and there
are other OOS PHE2 or PH33 candidates that may still be
successfully recovered, choose a new PHE2 or PH33 and RETURN to
Step 2.
............................................................................................................................................................
11
The PHE2 or PH33 is in a trouble analysis state. SEEK TECHNICAL
ASSISTANCE according to local procedures for the affected PH.
Resolve Protocol Handler Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
7-38
Lucent Technologies 235-200-118
Issue 3.02B, March 2007