EasyManua.ls Logo

Lucent Technologies 5ESS - Page 475

Lucent Technologies 5ESS
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
............................................................................................................................................................
12
If the PHE2 is degraded and a service selection change report is
generated indicating that the Ethernet link is down, then determine the
cause, for example, loose or faulty cable, and repair it, if possible. A
corresponding
REPT PSELNK report should have been generated.
However, it is possible that the LLE2 paddleboard is faulty. Refer to
the SIP for Packet Trunking Corrective Maintenance procedure,
Resolve LLE2 Paddleboard Problems, 235-200-118.
............................................................................................................................................................
13
Stop. You have completed this procedure.
Resolve Protocol Handler Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
235-200-118
Issue 3.02B, March 2007
Lucent Technologies
7-39
E ND OF S TEPS
.........................................................................................................................................................................................................................................................

Table of Contents

Related product manuals