If either NLI was repaired or restored, recheck the target GQPH
QPipe status:
OP:STATUS,GQPHQPIPE,QPIPE=a-b-c-d-e;
Where:
a = Global switch module number
b = Packet switch unit 2 number
c = PSU2 shelf number
d = GQPH channel group number
e = QLPS network number
If the resultant state is
NOT OOS-QLPSLB or OOS-LVL1-FRAME,
then RETURN to Step 1 because the status of multiple GQPH QPipes
may have been affected by hardware reconfigurations.
Otherwise, attempt to conditionally switch QLPSs in the target
network:
SW:QLPS=0-d;
If the switch is successful, obtain of the QPipe
OP:STATUS,GQPHQPIPE,QPIPE=a-b-c-d-e;
Where:
a = Global switch module number
b = Packet switch unit 2 number
c = PSU2 shelf number
d = GQPH channel group number
e = QLPS network number
If the resultant state is
NOT OOS-QLPSLB or OOS-LVL1-FRAME,
CONTINUE this procedure for further recovery.
Otherwise, RETURN to Step 1 because the status of multiple GQPH
QPipes may have been affected by hardware reconfigurations.
............................................................................................................................................................
10
An OOS-LVL1-PATH GQPH QPipe has failed a restoral because the
nailed-up TSI-QPH path could not be established. An assert may be
produced, pointing to an ODD problem, or there may be a subtle error
in timeslot assignment. This step may also be reached if previous
Resolve GQPH QPipe Problems
Maintenance Considerations
....................................................................................................................................................................................................................................
7-54
Lucent Technologies 235-200-118
Issue 3.02B, March 2007