y = SIP (Service Type)
Examine the
FINAL STATUS entry of the GQPH QPipe listed and
take appropriate action.
• If the final status is
ACT and the RECOVERY is not
TRANSIENT OUTAGE, then the GQPH QPipe has automatically
recovered by reconfiguring parent hardware. Independent craft
personnel actions will be take to repair any faulty hardware but
no direct action need to be taken because GMT has not been
permanently impacted.
• If the final status is
ACT and the RECOVERY is TRANSIENT
OUTAGE
, then the GQPH QPipe has automatically recovered but
the reason for the outage is unknown.
No direct action need be taken because GMT has not been
permanently impacted, but the reason for outage should be
investigated. Gather supplementary error reports with headers and
SEEK TECHNICAL ASSISTANCE according to local
procedures.
• If the final status is
not ACT, then one or more GQPH QPipes
on a particular GSM has been removed. Record the inactive
GQPH QPipes and refer to the SIP for Packet Trunking
Corrective Maintenance procedure, Resolve GQPH QPipe
Problems, 235-200-118, to recover the identified GQPH QPipes.
............................................................................................................................................................
5
If the supplementary unalarmed error report with headers generated is:
REPT ERROR DATA GQPHPIPE=a-b-c-d-e
Where:
a = Global switch module number
b = Packet switch unit 2 number
c = PSU2 shelf
d = GQPH channel group
e = QLPS network
Refer to the SIP for Packet Trunking Corrective Maintenance
procedure, Resolve GQPH QPipe Problems, 235-200-118, to possibly
recover the GQPH QPipes. However, the failure of identified GQPH
QPipes should be investigated. SEEK TECHNICAL ASSISTANCE
according to local procedures.
Analyze General Message Transport (GMT)
Error Reports
Maintenance Considerations
....................................................................................................................................................................................................................................
7-62
Lucent Technologies 235-200-118
Issue 3.02B, March 2007