Matrix PRASAR UCS System Manual 1071
Notification Settings
• Click Notification Settings to expand.
If SNMP version is set as SNMPv1, configure the following parameters.
• Select Enable Notification check box, if you want PRASAR UCS to generate Trap message for an
error.
• You must configure the Notification Destination IP Address and Notification Destination Port of
the Manager or of any other device where you want to receive the trap messages.
PRASAR UCS will send the notification (error message) to the destination configured.
Valid range of the Notification Destination Port is 162 or 0-65535. Default port is 162.
• Click Submit button to save the settings.
If SNMP version is set as SNMPv2c or SNMPv3, configure the following parameters.
• Select Enable Notification check box, if you want PRASAR UCS to generate Trap or Inform message
for an error.
• Select the Notification Type. You may select Trap or Inform.
If you want the system to send notification message without acknowledgment, select Trap.
If you want the system to send notification message with acknowledgment, select Inform.
• If you select Inform as the Notification Type, you must configure Retry Attempts and Retry Interval.
If acknowledgment is not received from the Manager for the notification sent, the system will keep
retransmitting the message for the number of attempts you have configured as the Retry Attempts.
Default: 3.
The system will retransmit the messages at regular time intervals you have configured as Retry
Interval. Default: 10 seconds.
• You must configure the Notification Destination IP Address and Notification Destination Port of
the Manager or of any other device where you want to receive the trap messages.
PRASAR UCS will send the notification (error message) to the destination configured.
Valid range of the Notification Destination Port is 162 or 0-65535. Default port is 162.