Matrix PRASAR UCS System Manual 113
Configuring Redundancy Parameters
In this topic we will explain how to configure the Redundancy parameters. To know about the Redundancy feature
and how it works, refer to “Redundancy”.
How to configure
For this feature to work,
• You must purchase two SPARK200 servers.
• Make sure that the same Firmware Version V2.0 or later is installed in both the servers.
• Activate the Redundancy license in only one Server (preferably the one with other licensed features). To
know more, refer to “License Management”.
• Configure the Virtual IP for the LAN/WAN port as per your network scenario. To know more, refer to
“Configuring Network Parameters”.
• It is recommended to configure the Primary Server first and then configure the Backup Server. To know
more, refer to “Configuring the Servers”.
PRASAR UCS supports redundancy only when the Connection Type configured for the WAN Port is Static,
if WAN is selected as the Redundancy On Option.
Configuring the Servers
• Connect the LAN port of the server which is to be configured as the Primary Server to a PC without
connecting the other server.
• Enter https://192.168.2.100 (Default IP of the LAN port.) in the address bar of the browser.
• Login as System Engineer.
• Under Configuration, click Network Parameters.
• Click Parameter. The Network Parameters page opens.
• Click LAN Port (IPv4 settings) to expand. Enter the IP address of the LAN port)
• Click WAN Port (IPv4 settings) to expand. Enter the IP address of the WAN port.