Matrix PRASAR UCS System Manual 1259
• Filter Settings = src 192.168.1.191 or dst 192.168.1.191
To capture packets which are transmitted from the system for particular port number only, from IP
address 192.168.1.191 and port number 161
• Filter Settings = src 192.168.1.191 and port 161
It is not mandatory to set Filters. When the Filter Settings field is left blank, the system will capture all
packets.
• Enable Promiscuous Mode: Select the Enable Promiscuous Mode check box, if required.
When you enable Promiscuous mode, the PRASAR UCS will capture all network traffic. However, this
will work only in a non-switched environment.
When Promiscuous Mode check box is disabled, the system will capture only traffic that is directly
related to it. Only traffic to, from or routed through the PRASAR UCS will be picked up by the PCAP
Trace.
'Filter Settings' and 'Promiscuous Mode' (enabled) will not be cleared during power down.
• Click the Start button to begin the capturing of the packets.
• Click the Stop button to stop packet capture.
OR
Wait for the system to stop packet capturing. The system stops packet capturing once the maximum
allotted memory of 10 MB (RAM) is utilized.
• Total Bytes: Bytes captured as per the filter setting will be displayed as Total Bytes.
Capturing of packets will not stop if you open any other page of Jeeves. So, you may continue using
Jeeves for any other purpose while PCAP Trace is being used.
• When the packet capturing is stopped (by you or the system), click the Save Trace File button to save
the files on the PC.
The current packets captured will not be deleted after you have saved the trace file. The current packets
will be deleted when you start the PCAP capture again.
• Now, you can open the downloaded trace file using Wireshark or Ethereal or any other similar software
which supports opening of trace files.
If you select Remote as the Location:
Configure the following:
• Listening Interface: Select WAN or LAN as per your requirement.
• Listening Port: Enter the port number using which you want PRASAR UCS to send the packets to the
remote device. Make sure this port number is also configured in the remote device.