Hardware
112
Detected abnormal
temperature..
Confirm that dust or dirt is not attached on the
internal cooling fan. Confirm that the cooling
fan is connected firmly as well. Replace it or
contact the maintenance service company if
the problem is not solved.
Detected abnormal voltage. Contact the maintenance service company.
Detected individual failure in
power supply unit.
Detected fan alarm.
Detected temperature
warning.
Check the slot of failed power supply unit and
replace it or contact the maintenance service
company.
Detected voltage warning Contact the maintenance service company.
Lighting in amber
Hard disk drive failed. The operation can continue even if one hard
disk drive fails depending on the RAID level
when the drive is configured in the RAID
system. However, it is recommended to
replace the disk immediately and rebuild the
hard disk drive (Hard disk drive is
hot-swappable and can be replaced online).